Practice Question on sampling and reconstruction (related to Nyquist rate)

The signal

$ x(t)= \frac{\sin (3 \pi t)}{\pi t} $

is sampled with a sampling period T. For what values of T is it possible to reconstruct the signal from its sampling?


Share your answers below

You will receive feedback from your instructor and TA directly on this page. Other students are welcome to comment/discuss/point out mistakes/ask questions too!


Answer 1

from the Table

x(w) = u(w+3pi)-u(w-3pi)


Thus the signal is bandlimited with a wm = 3pi

We must sample above the Nyquist Rate which is equal to 2wm or 6pi

ws > 6pi

T = 2pi/ws < 2/6 = 1/3


The signal can be reconstructed for all T < 1/3. --Ssanthak 12:09, 20 April 2011 (UTC)